Schneider Electric Linergy TR terminal block, rated 309 A. Screw terminal, Linergy TR terminals blocks, feed through, 2 points, lug-connector, 150mm², grey.
Screw terminal, Linergy TR terminals blocks, feed through, 2 points, lug-connector, 150mm², grey. Genuine Schneider Electric product supplied by United Force.
Technical specifications
| Range | Linergy |
|---|
| Product name | Linergy TR |
|---|
| Product or component type | Terminal block |
|---|
| Device short name | TRV |
|---|
| Accessory / separate part category | Connection accessory |
|---|
| Terminal block type | Passthrough |
|---|
| Terminal block level | 1 |
|---|
| Mounting mode | Clip-on |
|---|
| Nominal cross section | 150 mm² |
|---|
| Length | 235 mm |
|---|
| Colour | Grey |
|---|
| Quantity per set | Set of 5 |
|---|
| Width | 41 mm |
|---|
| Height | 84.5 mm |
|---|
| Connections - terminals | 1 x lug: upstream (M10) · 1 x screw terminal: downstream (M10) |
|---|
| number of connections | 2 |
|---|
| Connection position | Sideways |
|---|
| Number of measurement input | 0 |
|---|
| Cable cross section | 6…150 mm², solid · 6…150 mm², flexible without cable end |
|---|
| Tightening torque | 10…20 N.m upstream · 10…20 N.m downstream |
|---|
| Wire stripping length | 29 mm |
|---|
| Tool type | Connection: screwdriver · Disconnection: screwdriver |
|---|
| [Ue] rated operational voltage | 1100 V IECEx conforming to EN/IEC 60947-7-1 · 600 V UL recognized · 600 V CSA |
|---|
| [In] rated current | 309 A IECEx conforming to EN/IEC 60947-7-1 · 310 A UL recognized · 310 A CSA |
|---|
| Material | Polyamide 6/6: insulating case · Copper alloy: connector and screw · Copper alloy: commoning link · Chromium-nickel steel: spring |
|---|
| Dielectric loss | 0.01 at 1 MHz conforming to IEC 60250 · 0.01 at 1 MHz conforming to VDE 0303-T4 |
|---|
| Dielectric constant | 3.7 at 1 MHz |
|---|
| Creep resistance | 500 CTI (> 400 kB) conforming to IEC 60093 · 500 CTI (> 400 kB) conforming to VDE 0303-T30 |
|---|
| Surface resistance | 1000 GΩ conforming to IEC 60093 · 1000 GΩ conforming to VDE 0303-T30 |
|---|
| Resistivity | 10000 MΩ.m conforming to IEC 60093 · 10000 MΩ.m conforming to VDE 0303-T30 |
|---|
| Flame retardance | V0, thickness0.8 mm conforming to UL 94 |
|---|
| Range compatibility | PrismaSeT G · PrismaSeT P · PrismaSet HD · PanelSeT |
|---|
| Product compatibility | Spacial enclosures |
|---|
| Product certifications | GL · CSA · UL |
|---|
| Dielectric strength | 1000 V conforming to IEC 60243-1 |
|---|
| Ambient air temperature for operation | -60…105 °C conforming to IEC 60947-1 |
|---|
| Unit Type of Package 2 | BB1 |
|---|
| Number of Units in Package 2 | 5 |
|---|
| Package 2 Height | 9.300 cm |
|---|
| Package 2 Width | 24.000 cm |
|---|
| Package 2 Length | 26.000 cm |
|---|
| Package 2 Weight | 1.622 kg |
|---|
| Unit Type of Package 3 | S06 |
|---|
| Number of Units in Package 3 | 180 |
|---|
| Package 3 Height | 75.000 cm |
|---|