Schneider Electric ComPacT NSX circuit breaker, rated 25 A. Circuit breaker, ComPacT NSX100HB1, 75kA/690VAC, 3 poles, MicroLogic 6.2E-M trip unit 25A.
Circuit breaker, ComPacT NSX100HB1, 75kA/690VAC, 3 poles, MicroLogic 6.2E-M trip unit 25A. Genuine Schneider Electric product supplied by United Force.
Technical specifications
| Range | ComPacT |
|---|
| Product name | ComPacT NSX |
|---|
| Device short name | NSX100HB1 |
|---|
| Product or component type | Circuit breaker |
|---|
| Device application | Motor protection |
|---|
| Poles description | 3P |
|---|
| Protected poles description | 3D |
|---|
| [In] rated current | 25 A at 65 °C |
|---|
| [Ue] rated operational voltage | 690 V AC 50/60 Hz |
|---|
| Network type | AC |
|---|
| Network frequency | 50/60 Hz |
|---|
| Suitability for isolation | Yes conforming to EN/IEC 60947-2 |
|---|
| Utilisation category | Category A |
|---|
| Breaking capacity | 85 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 · 80 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 · 75 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 |
|---|
| Breaking capacity code | HB1 75 kA 690 V AC |
|---|
| Trip unit name | MicroLogic 6.2 E-M |
|---|
| Trip unit technology | Electronic |
|---|
| Trip unit protection functions | LSIG |
|---|
| Control type | Toggle |
|---|
| Circuit breaker mounting mode | Fixed |
|---|
| [Ui] rated insulation voltage | 800 V AC 50/60 Hz |
|---|
| [Uimp] rated impulse withstand voltage | 8 kV |
|---|
| [Ics] rated service breaking capacity | 85 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 · 80 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2 · 75 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 |
|---|
| Mechanical durability | 20000 cycles |
|---|
| Electrical durability | 20000 cycles at 440 V In/2 · 10000 cycles at 440 V In · 10000 cycles at 690 V In/2 · 5000 cycles at 690 V In |
|---|
| Power dissipation per pole | 1.3 W |
|---|
| Mounting support | Backplate |
|---|
| Mounting position | Horizontal and vertical · Flat on the back |
|---|
| Upside connection | Front |
|---|
| Downside connection | Front |
|---|
| Connection pitch | 35 mm |
|---|
| Protection type | L : for overload protection (long time) · So : for short time short-circuit protection · I : for instantaneous short-circuit protection · G : for ground fault protection |
|---|
| Trip unit rating | 25 A at 65 °C |
|---|
| Motor tripping class | 5 · 10 · 30 · 20 |
|---|
| Complementary motor protection | Phase unbalance · Stalled rotor · Protracted starting time · Underload |
|---|
| Long-time pick-up adjustment type Ir (thermal protection) | Adjustable 9 settings |
|---|
| [Ir] long-time protection pick-up adjustment range | 12...25 A |
|---|
| Long-time protection delay adjustment type tr | Adjustable |
|---|
| [tr] long-time delay adjustment range | 120 s at 1.5 x Ir for trip class 5 · 6.5 s at 6 x Ir for trip class 5 · 5 s at 7.2 x Ir for trip class 5 · 240 s at 1.5 x Ir for trip class 10 · 13.5 s at 6 x Ir for trip class 10 · 10 s at 7.2 x Ir for trip class 10 · 480 s at 1.5 x Ir for trip class 20 · 26 s at 6 x Ir for trip class 20 · 20 s at 7.2 x Ir for trip class 20 · 720 s at 1.5 x Ir for trip class 30 · 38 s at 6 x Ir for trip class 30 · 30 s at 7.2 x Ir for trip class 30 |
|---|
| Thermal memory | 20 minutes before and after tripping |
|---|
| Short-time protection pick-up adjustment type Isd | Adjustable |
|---|
| [Isd] Short-time protection pick-up adjustment range | 5...13 x Ir |
|---|
| Short-time protection delay adjustment type tsd | Fixed |
|---|
| Instantaneous protection pick-up adjustment type Ii | Fixed |
|---|
| [Ii] instantaneous protection pick-up adjustment range | 425 A |
|---|