Schneider Electric Easy TeSys contactor, rated 6 A. Contactor,Easy TeSys Control,LC1E,3P(3NO),AC-3/AC-3e,<=440V,6A,24V DC coil,1 NC auxiliary contact.
Contactor,Easy TeSys Control,LC1E,3P(3NO),AC-3/AC-3e,<=440V,6A,24V DC coil,1 NC auxiliary contact. Genuine Schneider Electric product supplied by United Force.
Technical specifications
| Range | Easy TeSys |
|---|
| Range of product | Easy TeSys Control |
|---|
| Product or component type | Contactor |
|---|
| Device short name | LC1E |
|---|
| Contactor application | Motor control · Resistive load |
|---|
| Utilisation category | AC-3 · AC-3e · AC-1 |
|---|
| Poles description | 3P |
|---|
| [Ue] rated operational voltage | Power circuit: <= 690 V AC 50/60 Hz |
|---|
| [Ie] rated operational current | 6 A (at <55 °C) at <= 440 V AC AC-3 for power circuit · 6 A (at <55 °C) at <= 440 V AC AC-3e for power circuit · 20 A (at <55 °C) at <= 440 V AC AC-1 for power circuit |
|---|
| [Uc] control circuit voltage | 24 V DC |
|---|
| Motor power kW | 1.1 kW at 220/230 V AC 50/60 Hz · 2.2 kW at 380/400 V AC · 2.2 kW at 415/440 V AC · 3 kW at 500 V AC · 3 kW at 660/690 V AC · 3 kW at 660...690 V |
|---|
| Pole contact composition | 3 NO |
|---|
| [Ith] conventional free air thermal current | 20 A (at 55 °C) for power circuit |
|---|
| Irms rated making capacity | 78 A at 440 V AC for power circuit conforming to IEC 60947-4-1 |
|---|
| Rated breaking capacity | 51 A at 440 V for power circuit conforming to IEC 60947 |
|---|
| [Icw] rated short-time withstand current | 80 A 40 °C - 10 s for power circuit · 45 A 40 °C - 60 s for power circuit · 20 A 40 °C - 600 s for power circuit |
|---|
| Associated fuse rating | 12 A gG at <= 690 V coordination type 1 for power circuit · 10 A gG at <= 690 V for auxiliary contact circuit conforming to IEC 60947-5-1 |
|---|
| Average impedance | 2.5 mOhm - Ith 20 A 50 Hz for power circuit |
|---|
| Power dissipation per pole | 0.09 W AC-3 · 1 W AC-1 |
|---|
| [Ui] rated insulation voltage | 690 V conforming to IEC 60947-4-1 |
|---|
| Overvoltage category | III |
|---|
| Pollution degree | 3 |
|---|
| [Uimp] rated impulse withstand voltage | 6 kV coil not connected to the power circuit conforming to IEC 60947 |
|---|
| Mechanical durability | 10000000 cycles |
|---|
| Electrical durability | 1400000 cycles AC-3 at Ue <= 440 V · 150000 cycles AC-1 at Ue <= 440 V |
|---|
| Control circuit type | DC |
|---|
| Control circuit voltage limits | 0.85...1.1 Uc (-5…55 °C):operational DC · 0.1...0.25 Uc (-5…55 °C):drop-out DC |
|---|
| Inrush power in W | 6 W (at 20 °C) |
|---|
| Hold-in power consumption in W | 6 W at 20 °C |
|---|
| Operating time | 53...72 ms on closing · 16...24 ms on opening |
|---|
| Time constant | 28 ms |
|---|
| Maximum operating rate | 1800 cyc/h 60 °C |
|---|
| Connections - terminals | Power circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible without cable end · Power circuit: screw clamp terminals 2 1…2.5 mm² - cable stiffness: flexible without cable end · Power circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible with cable end · Power circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: flexible with cable end · Power circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: solid without cable end · Power circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: solid without cable end · Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible without cable end · Control circuit: screw clamp terminals 2 1…2.5 mm² - cable stiffness: flexible without cable end · Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible with cable end · Control circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: flexible with cable end · Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: solid without cable end · Control circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: solid without cable end |
|---|
| Tightening torque | Power circuit: 1.7 N.m · Control circuit: 1.7 N.m |
|---|
| Auxiliary contact composition | 1 NC |
|---|
| Minimum switching voltage | 17 V for auxiliary contact circuit |
|---|
| Minimum switching current | 5 mA for auxiliary contact circuit |
|---|
| Insulation resistance | > 10 MOhm for auxiliary contact circuit |
|---|
| Mounting support | DIN rail · Plate |
|---|
| Standards | EN/IEC 60947-1 · EN/IEC 60947-4-1 · EN/IEC 60947-5-1 · GB/T 14048.1 · GB/T 14048.4 · GB/T 14048.5 |
|---|
| Product certifications | CB Scheme · CCC · CE · EAC |
|---|
| IP degree of protection | IP20 conforming to IEC 60529 |
|---|
| Protective treatment | TH conforming to IEC 60068-2-30 test Db |
|---|
| Permissible ambient air temperature around the device | -20…70 °C at Uc · -60…80 °C storage · -5…55 °C operation |
|---|
| Operating altitude | 3000 m without derating |
|---|