Schneider Electric TeSys contactor, rated 20 A. Contactor, TeSys K, 4P(4NO), AC-1, 440V 20A, 220..230V AC standard coil.
Contactor, TeSys K, 4P(4NO), AC-1, 440V 20A, 220...230V AC standard coil. Genuine Schneider Electric product supplied by United Force.
Technical specifications
| Range | TeSys |
|---|
| Product or component type | Contactor |
|---|
| Device application | Control |
|---|
| Contactor application | Resistive load |
|---|
| Utilisation category | AC-1 |
|---|
| Poles description | 4P |
|---|
| power pole contact composition | 4 NO |
|---|
| [Ue] rated operational voltage | Power circuit: <= 690 V AC <= 400 Hz · Signalling circuit: <= 690 V AC <= 400 Hz |
|---|
| [Ie] rated operational current | 20 A (at <60 °C) at <= 690 V AC AC-1 for power circuit |
|---|
| Control circuit type | AC at 50/60 Hz |
|---|
| [Uc] control circuit voltage | 220...230 V AC 50/60 Hz |
|---|
| [Uimp] rated impulse withstand voltage | 8 kV |
|---|
| Overvoltage category | III |
|---|
| [Ith] conventional free air thermal current | 20 A (at 60 °C) for power circuit · 10 A (at 50 °C) for signalling circuit |
|---|
| Irms rated making capacity | 144 A AC for power circuit conforming to IEC 60947 |
|---|
| Rated breaking capacity | 110 A at 440 V conforming to IEC 60947 · 80 A at 500 V conforming to IEC 60947 · 70 A at 660...690 V conforming to IEC 60947 |
|---|
| [Icw] rated short-time withstand current | 115 A 50 °C - 1 s for power circuit · 105 A 50 °C - 5 s for power circuit · 100 A 50 °C - 10 s for power circuit · 75 A 50 °C - 30 s for power circuit · 55 A 50 °C - 1 min for power circuit · 50 A 50 °C - 3 min for power circuit · 25 A 50 °C - >= 15 min for power circuit |
|---|
| Associated fuse rating | 25 A gG at <= 440 V for power circuit · 25 A aM for power circuit |
|---|
| Average impedance | 3 mOhm - Ith 20 A 50 Hz for power circuit |
|---|
| Inrush power in VA | 30 VA (at 20 °C) |
|---|
| Hold-in power consumption in VA | 4.5 VA (at 20 °C) |
|---|
| Heat dissipation | 1.3 W |
|---|
| Control circuit voltage limits | Operational: 0.8...1.15 Uc (at = 0.20 Uc (at <50 °C) |
|---|
| Connections - terminals | Screw clamp terminals 1 cable(s) 1.5…4 mm²solid · Screw clamp terminals 1 cable(s) 0.75…4 mm²flexible without cable end · Screw clamp terminals 1 cable(s) 0.34…2.5 mm²flexible with cable end · Screw clamp terminals 2 cable(s) 1.5…4 mm²solid · Screw clamp terminals 2 cable(s) 0.75…4 mm²flexible without cable end · Screw clamp terminals 2 cable(s) 0.34…1.5 mm²flexible with cable end |
|---|
| Maximum operating rate | 3600 cyc/h |
|---|
| Coil technology | Without built-in suppressor module |
|---|
| Signalling circuit frequency | <= 400 Hz |
|---|
| Operating time | 10...20 ms coil de-energisation and NO opening · 10...20 ms coil energisation and NO closing |
|---|
| Safety reliability level | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 · B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 |
|---|
| Mechanical durability | 10 Mcycles |
|---|
| Electrical durability | 0.3 Mcycles 20 A AC-1 at Ue <= 690 V |
|---|
| Mechanical robustness | Shocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 · Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 · Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 · Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 · Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 · Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 · Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 · Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6 |
|---|
| Height | 58 mm |
|---|
| Width | 45 mm |
|---|
| Depth | 57 mm |
|---|
| Standards | EN/IEC 60947-4-1 · GB/T 14048.4 · UL 60947-4-1 · CSA C22.2 No 60947-4-1 · JIS C8201-4-1 · IEC 60335-1:Clause 30.2 · IEC 60335-2-40:Annex JJ · UL 60335-2-40:Annex JJ |
|---|
| Product certifications | CB Scheme · CCC · UL · CSA · EAC · CE · UKCA |
|---|
| Protective treatment | TC conforming to IEC 60068 · TC conforming to DIN 50016 |
|---|
| Operating altitude | 2000 m without derating |
|---|
| Flame retardance | V1 conforming to UL 94 · Requirement 2 conforming to NF F 16-101 · Requirement 2 conforming to NF F 16-102 |
|---|
| Warranty (in months) | 18 |
|---|