Schneider Electric EasyPact CVS circuit breaker, rated 400 A. circuit breaker, EasyPact CVS400N, 50kA at 415VAC, 400A, ETS 2.3 electronic trip unit, 3P3d.
circuit breaker, EasyPact CVS400N, 50kA at 415VAC, 400A, ETS 2.3 electronic trip unit, 3P3d. Genuine Schneider Electric product supplied by United Force.
Technical specifications
| Range | EasyPact |
|---|
| Range of product | EasyPact CVS400...630 |
|---|
| Product name | EasyPact CVS |
|---|
| Device short name | CVS400N |
|---|
| Product or component type | Circuit breaker |
|---|
| Device application | Distribution |
|---|
| Poles description | 3P |
|---|
| Protected poles description | 3D |
|---|
| Earth leakage protection (Vigi add on) | Without |
|---|
| [In] rated current | 400 A at 40 °C |
|---|
| Network type | AC |
|---|
| Utilisation category | Category A |
|---|
| [Icu] Breaking capacity | 70 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 · 50 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 · 42 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 |
|---|
| Trip unit name | ETS 2.3 |
|---|
| Trip unit technology | Electronic |
|---|
| Trip unit rating | 400 A at 40 °C |
|---|
| Protection type | Short time short-circuit protection · Overload protection (long time) · Instantaneous short-circuit protection |
|---|
| [Uimp] rated impulse withstand voltage | 8 kV conforming to EN/IEC 60947-2 |
|---|
| Network frequency | 50/60 Hz |
|---|
| Breaking capacity code | N |
|---|
| [Ics] rated service breaking capacity | 70 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 · 50 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 · 32 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 |
|---|
| Mechanical durability | 15000 cycles |
|---|
| Electrical durability | 6000 cycles 415 V In conforming to IEC 60947-2 |
|---|
| Trip unit protection functions | LSoI |
|---|
| Control type | Toggle |
|---|
| Long time pick-up adjustment type Ir | Adjustable 9 settings |
|---|
| Long time pick-up adjustment range | 160…400 A |
|---|
| Long time delay adjustment type | Fixed |
|---|
| [tr] long-time delay adjustment range | 5.5 s at 7.2 x Ir · 8 s at 6 x Ir · 200 s at 1.5 x Ir |
|---|
| Thermal memory | Yes |
|---|
| Short-time pick-up adjustment type Isd | Adjustable 9 settings |
|---|
| [Isd] short-time pick-up adjustment range | 1.5...10 x Ir |
|---|
| Short-time delay adjustment type | Fixed |
|---|
| Instantaneous pick-up adjustment type Ii | Fixed |
|---|
| Instantaneous pick-up adjustment range | 11 x In |
|---|
| Contact position indicator | Yes |
|---|
| Mounting support | Backplate |
|---|
| Mounting mode | Fixed |
|---|
| Upside connection | Front |
|---|
| Downside connection | Front |
|---|
| Connections - terminals | Screw connection |
|---|
| Connection pitch | 45 mm |
|---|
| Compatibility code | CVS400 |
|---|
| Width | 140 mm |
|---|
| Depth | 110 mm |
|---|