Schneider Electric discrete input module. Discrete input module, Modicon X80, 32 inputs, 24V DC positive, for severe environments.
Discrete input module, Modicon X80, 32 inputs, 24V DC positive, for severe environments. Genuine Schneider Electric product supplied by United Force.
Technical specifications
| Range of product | Modicon X80 |
|---|
| Product or component type | Discrete input module |
|---|
| Device application | Industrial application in severe environment |
|---|
| Discrete input number | 32 |
|---|
| Discrete input voltage | 24 V DC for isolated |
|---|
| Discrete input logic | Positive logic (sink) |
|---|
| Input wiring mode | 2 or 3 wires |
|---|
| Discrete input current | 2.5 mA at 24 V DC |
|---|
| Voltage state 0 guaranteed | < 5 V |
|---|
| Current state 1 guaranteed | >= 2 mA |
|---|
| Current state 0 guaranteed | <= 0.5 mA |
|---|
| Input impedance | 9600 Ohm |
|---|
| Paralleling of inputs | No |
|---|
| Input protection type | Reverse polarity protection |
|---|
| Insulation resistance | > 10 MOhm 500 V DC |
|---|
| DC typical response time | 4 ms |
|---|
| DC maximum response time | 7 ms |
|---|
| Sensor power supply | : 19…30 V |
|---|
| Typical current consumption | 121 mA DC |
|---|
| Current consumption | 160 mA at 3.3 V DC |
|---|
| Power dissipation in W | 3.9 W |
|---|
| Isolation between channels and bus | 1500 V for 1 minute |
|---|
| MTBF reliability | 905000 H |
|---|
| Voltage detection threshold | 18 V DC sensor OK |
|---|
| Local signalling | 1 LED (green) for module operating (RUN) · 1 LED per channel (green) for channel diagnostic · 1 LED (red) for module error (ERR) · 1 LED (red) for module I/O |
|---|
| Height | 134.6 mm |
|---|
| Width | 32 mm |
|---|
| Depth | 86 mm |
|---|
| Product weight | 0.112 kg |
|---|
| IP degree of protection | IP20 |
|---|
| Protective treatment | Conformal coating |
|---|
| Marking | CE · UKCA · CULus · RCM · EAC |
|---|
| Product certifications | ATEX zone 2 · IECEx zone 2 · CCC Ex zone 2 (pending) · CULus HazLoc |
|---|
| Standards | IEC 61131-2 |
|---|
| Directives | 2014/35/EU - low voltage directive · 2014/30/EU - electromagnetic compatibility |
|---|
| Dielectric strength | 1500 V AC at 50/60 Hz 1 minute, primary/secondary · 500 V DC 1 minute, between group of channels |
|---|
| Ambient air temperature for operation | -25…70 °C |
|---|
| Relative humidity | 5…95 % at -25…70 °C without condensation |
|---|
| Operating altitude | 0...2000 m · 2000...5000 m with derating |
|---|
| Environmental characteristic | Gas resistant class Gx · Gas resistant class 3C4 · Dust resistant class 3S4 · Sand resistant class 3S4 · Salt resistant level 2 · Mold growth resistant class 3B2 · Fungal spore resistant class 3B2 |
|---|
| Unit Type of Package 2 | S02 |
|---|
| Number of Units in Package 2 | 15 |
|---|
| Package 2 Height | 15.000 cm |
|---|
| Package 2 Width | 30.000 cm |
|---|
| Package 2 Length | 40.000 cm |
|---|