Schneider Electric counter module. counter module, Modicon M340, high speed, 2 channels, hardened.
counter module, Modicon M340, high speed, 2 channels, hardened. Genuine Schneider Electric product supplied by United Force.
Technical specifications
| Range of product | Modicon M340 automation platform |
|---|
| Product or component type | Counter module |
|---|
| Product specific application | For severe environments |
|---|
| Number of channels | 2 |
|---|
| Maximum counting frequency | 60000 Hz |
|---|
| Number of inputs | 6 |
|---|
| Input compatibility | 19.2…30 V 2-wire/3-wire proximity sensor · incremental encoder with push-pull outputs, 10...30 V totem pole |
|---|
| Input voltage | 24 V DC type 3 |
|---|
| Number of outputs | 2 |
|---|
| Output voltage | 24 V DC |
|---|
| Counter functions | Ratio count · Frequency meter · Down counting · 32-bit counter counting · Loop (modulo) counting · Measure time periods · Count events · Width modulation |
|---|
| Cycle time | 1 ms |
|---|
| Isolation voltage | 1500 V for 60 s |
|---|
| Input type | 3 auxiliary input · 3 high speed |
|---|
| Input voltage limits | 24 V DC |
|---|
| Input current | 2 mA at 11 V |
|---|
| Voltage state 1 guaranteed | 11...30 V DC |
|---|
| Current state 1 guaranteed | > 2 mA (for U >= 11V) |
|---|
| Voltage state 0 guaranteed | < 5 V DC |
|---|
| Current state 0 guaranteed | < 1.5 mA |
|---|
| Discrete output logic | Positive or negative configurable |
|---|
| Maximum output current | 2 A per module · 0.5 A per output |
|---|
| Output voltage limits | 19.2...30 V |
|---|
| Maximum load current | 1 A per module · 0.5 A per output |
|---|
| Maximum leakage current | 0.1 mA at state 0 |
|---|
| Maximum voltage drop | <3 V at state 1 |
|---|
| Output overload protection | Integrated |
|---|
| Output short-circuit protection | 1.5 A integrated |
|---|
| Overlap time | 0.2 ms |
|---|
| Electrical connection | 1 connector with 10 pins for wiring auxiliary input and sensor power supply · 1 connector with 16 pins for wiring the sensors of counter 0 · 1 connector with 16 pins for wiring the sensors of counter 1 |
|---|
| Current consumption | 200 mA at 3.3 V DC bus · 40 mA at 24 V DC rack · 80 mA at 24 V DC sensor |
|---|
| Module format | Standard |
|---|
| Product weight | 0.112 kg |
|---|
| Ambient air temperature for operation | -25…70 °C |
|---|
| Relative humidity | 10…95 % without condensation |
|---|
| IP degree of protection | IP20 |
|---|
| Directives | 2014/35/EU - low voltage directive · 2014/30/EU - electromagnetic compatibility |
|---|
| Product certifications | CE · UL · CSA · RCM · EAC · Merchant Navy |
|---|
| Standards | IEC 61131-2 · IEC 61010-2-201 · UL 61010-2-201 · CSA C22.2 No 61010-2-201 · IACS E10 · EN/IEC 61000-6-5, interface type 1 and type 2 · EN/IEC 61850-3, location G |
|---|
| Environmental characteristic | Gas resistant class Gx conforming to ISA S71.04 · Gas resistant class 3C4 conforming to IEC 60721-3-3 · Dust resistant class 3S4 conforming to IEC 60721-3-3 · Sand resistant class 3S4 conforming to IEC 60721-3-3 · Salt resistant level 2 conforming to IEC 68252 · Mold growth resistant class 3B2 conforming to IEC 60721-3-3 · Fungal spore resistant class 3B2 conforming to IEC 60721-3-3 · Hazardous location class I division 2 |
|---|
| Protective treatment | Conformal coating |
|---|
| Unit Type of Package 2 | S02 |
|---|
| Number of Units in Package 2 | 15 |
|---|
| Package 2 Height | 15.000 cm |
|---|
| Package 2 Width | 30.000 cm |
|---|