Get to know your component / RM10TA00N
The details that matter. Schneider Electric 3-phase control relay. Harmony 3 phase voltage monitoring relay, Range 208 to 480 VAC, phase sequence, phase failure, Phase imbalance, 1 CO.
Complete product informationProduct description and supplied technical information Harmony 3 phase voltage monitoring relay, Range 208 to 480 VAC, phase sequence, phase failure, Phase imbalance, 1 CO. Genuine Schneider Electric product supplied by United Force.
Technical specifications Range of product Harmony Control Relays Relay type Control relay Relay name RM10TA Product or component type 3-phase control relay Relay monitored parameters Phase sequence · Phase failure detection · Asymmetry Product specific application For 3-phase supply Supply voltage limits 183…528 V AC, 3 phases Supply frequency 47...63 Hz Power consumption in VA 0…4.5 VA Measurement range 208...480 V AC Voltage detection threshold < 175 V AC Maximum measuring cycle 150 ms measurement cycle as true rms value Hysteresis 2 % Adjustment of asymmetry threshold 5...15 % of Un selected Repeat accuracy 0.5 % for input and measurement circuit · 3 % for time delay Measurement error < 0.05 %/°C with temperature variation · < 1 % over the whole range with voltage variation Time delay type Adjustable 0...15 s, +/- 10 % of the full scale value Reset time 1.5 s time delay Response time < 550 ms (in the event of a fault) Power on Delay 5 s Output contacts 1 C/O nominal output current 5 A Switching capacity in VA 1250 VA Electrical durability 100000 cycles Mechanical durability 10000000 cycles Setting accuracy of time delay 10 P Electromagnetic compatibility conforming to IEC 61000-6-4 · conforming to IEC 61000-6-3 · conforming to IEC 61000-6-2 Standards IEC 60255-1 Product certifications cULus · CE · UKCA · CCC Marking CULus · CE · UKCA · CCC Ambient air temperature for storage -20…80 °C Ambient air temperature for operation -15…60 °C Relative humidity 10…95 % Shock resistance 30 gn for 6 ms IP degree of protection IP20 (terminals) · IP40 (casing) Pollution degree 2 Overvoltage category II Dielectric test voltage 1.89 kV, 1 min AC 50 Hz Insulation resistance > 100 MOhm at 500 V DC [Ui] rated insulation voltage 400 V Connections - terminals Screw terminals, 2 x 0.5...2 x 1.5 mm² (20 AWG...16 AWG) solid with or without cable end Tightening torque 0.5…0.7 N.m Housing material Polycarbonate Local signalling LED (green) for ST (status) Mounting support 35 mm symmetrical DIN rail conforming to IEC 60715