Get to know your component / RM10TE00N
The details that matter. Schneider Electric 3-phase control relay. Harmony 3 phase voltage monitoring relay, Range 208 to 480 VAC, phase sequence, phase failure, Phase imbalance, 1 CO.
Complete product informationProduct description and supplied technical information Harmony 3 phase voltage monitoring relay, Range 208 to 480 VAC, phase sequence, phase failure, Phase imbalance, 1 CO. Genuine Schneider Electric product supplied by United Force.
Technical specifications Range of product Harmony Control Relays Relay type Control relay Relay name RM10TE Product or component type 3-phase control relay Relay monitored parameters Phase sequence · Phase failure detection · Asymmetry · Overvoltage and undervoltage detection Product specific application For 3-phase supply Supply voltage limits 183…528 V AC, 3 phases Supply frequency 47...63 Hz Power consumption in VA 0…4.5 VA Measurement range 208...480 V AC Voltage detection threshold < 175 V AC Maximum measuring cycle 150 ms measurement cycle as true rms value Hysteresis 2 % Repeat accuracy 0.5 % for input and measurement circuit · 3 % for time delay Measurement error < 0.05 %/°C with temperature variation · < 1 % over the whole range with voltage variation Time delay type Adjustable 0...100 s, +/- 10 % of the full scale value Reset time 1.5 s time delay Response time < 550 ms (in the event of a fault) Power on Delay 5 s Output contacts 1 C/O nominal output current 5 A Switching capacity in VA 1250 VA Electrical durability 100000 cycles Mechanical durability 10000000 cycles Setting accuracy of time delay 10 P Electromagnetic compatibility conforming to IEC 61000-6-4 · conforming to IEC 61000-6-3 · conforming to IEC 61000-6-2 Standards IEC 60255-1 Product certifications cULus · CE · UKCA · CCC Marking CULus · CE · UKCA · CCC Ambient air temperature for storage -20…80 °C Ambient air temperature for operation -15…60 °C Relative humidity 10…95 % Shock resistance 30 gn for 6 ms IP degree of protection IP20 (terminals) · IP40 (casing) Pollution degree 2 Overvoltage category II Dielectric test voltage 1.89 kV, 1 min AC 50 Hz Insulation resistance > 100 MOhm at 500 V DC [Ui] rated insulation voltage 400 V Connections - terminals Screw terminals, 2 x 0.5...2 x 1.5 mm² (20 AWG...16 AWG) solid with or without cable end Tightening torque 0.5…0.7 N.m Housing material Polycarbonate Local signalling LED (green) for ST (status) · LED (red) for overvoltage · LED (red) for undervoltage · LED (red) for alarm asymmentry failure triggered Mounting support 35 mm symmetrical DIN rail conforming to IEC 60715 Safety reliability data MTTFd = 158 years