Schneider Electric Acti9 energy meter, rated 125 A. iEM3300 energy meter - 125 A.
iEM3300 energy meter - 125 A. Genuine Schneider Electric product supplied by United Force.
Technical specifications
| Range | Acti9 |
|---|
| range of product | Acti9 iEM3000 |
|---|
| Product or component type | Energy meter |
|---|
| Device short name | iEM3300 |
|---|
| Market segment | Buildings small building cost management: billing: main incomer · Buildings small building cost management: billing: sub feeder · Buildings small building cost management: billing: panelboard · Buildings medium building cost management: billing: main incomer · Buildings medium building cost management: billing: sub feeder · Buildings medium building cost management: billing: panelboard · Buildings large building cost management: billing: main incomer · Buildings large building cost management: billing: sub feeder · Buildings large building cost management: billing: panelboard · Buildings multi-site cost management: billing: main incomer · Buildings multi-site cost management: billing: sub feeder · Buildings multi-site cost management: billing: panelboard · Data center cost management: billing · Healthcare cost management: billing · Industry cost management: billing · Buildings small building cost management: cost allocation: main incomer · Buildings small building cost management: cost allocation: sub feeder · Buildings small building cost management: cost allocation: panelboard · Buildings medium building cost management: cost allocation: main incomer · Buildings medium building cost management: cost allocation: sub feeder · Buildings medium building cost management: cost allocation: panelboard · Buildings large building cost management: cost allocation: main incomer · Buildings large building cost management: cost allocation: sub feeder · Buildings large building cost management: cost allocation: panelboard · Buildings multi-site cost management: cost allocation: main incomer · Buildings multi-site cost management: cost allocation: sub feeder · Buildings multi-site cost management: cost allocation: panelboard · Data center cost management: cost allocation · Healthcare cost management: cost allocation · Industry cost management: cost allocation |
|---|
| Poles description | 1P + N · 3P + N · 3P |
|---|
| Type of measurement | Active energy |
|---|
| Device application | Partial meter · Sub billing |
|---|
| Accuracy class | Class 1 active energy conforming to IEC 62053-21 · Class 1 active energy conforming to IEC 61557-12 |
|---|
| input type | Direct connection |
|---|
| [In] rated current | 125 A |
|---|
| Rated voltage | 100…277 V · 173…480 V |
|---|
| Network frequency | 50 Hz · 60 Hz |
|---|
| Technology type | Electronic |
|---|
| Display type | LCD display |
|---|
| Sampling rate | 32 samples/cycle |
|---|
| Measurement current | 0…125 A |
|---|
| Maximum value measured | 99999999.9 kWh |
|---|
| Communication port protocol | - |
|---|
| Communication port support | - |
|---|
| Local signalling | Green indicator light: power ON · Yellow flashing LED: accuracy checking |
|---|
| Number of inputs | 0 |
|---|
| Number of outputs | 0 |
|---|
| Mounting mode | Clip-on |
|---|
| Mounting support | DIN rail |
|---|
| Connections - terminals | Screw terminals 50 mm² cable(s) |
|---|
| Overvoltage category | III |
|---|
| Standards | BS EN 61557-12:2021 · IEC 61557-12:2021 · EN 61557-12:2021 · BS EN 61326-1 · IEC 61326-1 · EN 61326-1 · BS EN 62052-11:2020 · IEC 62052-11:2020 · EN 62052-11:2020 · BS EN 62053-21 · IEC 62053-21 · EN 62053-21 · BS EN 62052-31:2015 · IEC 62052-31:2015 · EN 62052-31:2015 · BS EN 61010-1:2010 · EN 61010-1:2010 · IEC 61010-1:2010 · UL 61010-1:2010 · BS EN 61010-2-30 · IEC 61010-2-30 · EN 61010-2-30 · UL 61010-2-30 · ANSI C12.16 |
|---|
| Product certifications | CE conforming to IEC 61010-1 (safety) · CE conforming to EN 61557-12 (power monitor) · CE conforming to EN/IEC 61326-1 (EMC) · UKCA conforming to BS EN 61010-1 (safety) · UKCA conforming to BS EN 61557-12 (power monitor) · UKCA conforming to BS EN 61326-1 (EMC) · CULus conforming to UL 61010-1 (safety) · CULus conforming to EN 61010-1 (safety) · EAC (sub-meter) · KZ conforming to NMI M 6-1 · KZ · NMI conforming to NMI M 6-1 |
|---|
| Compatibility code | IEM3300 |
|---|
| IP degree of protection | IP40 front panel: conforming to IEC 60529 · IP20 body: conforming to IEC 60529 |
|---|
| Pollution degree | 2 |
|---|
| Relative humidity | 5…95 % at 50 °C |
|---|
| Ambient air temperature for operation | -25…70 °C - IEC |
|---|
| Ambient air temperature for storage | -40…85 °C |
|---|
| Operating altitude | < 3000 m |
|---|
| Colour | White |
|---|
| 9 mm pitches | 14 |
|---|
| Width | 126 mm |
|---|
| Height | 103.2 mm |
|---|
| Depth | 69.3 mm |
|---|
| Unit Type of Package 2 | S03 |
|---|
| Number of Units in Package 2 | 18 |
|---|
| Package 2 Height | 30.000 cm |
|---|
| Package 2 Width | 30.000 cm |
|---|