Schneider Electric illuminated selector switch, rated 3 A. Illuminated selector switch, Harmony XB4, metal, red handle, 22mm, universal LED, 2 positions, 1NO + 1NC, 230..240V AC.
Illuminated selector switch, Harmony XB4, metal, red handle, 22mm, universal LED, 2 positions, 1NO + 1NC, 230...240V AC. Genuine Schneider Electric product supplied by United Force.
Technical specifications
| Range of product | Harmony XB4 |
|---|
| Product or component type | Illuminated selector switch |
|---|
| Device short name | XB4 |
|---|
| Bezel material | Chromium plated metal |
|---|
| Fixing collar material | Zamak |
|---|
| Head type | Standard |
|---|
| Mounting diameter | 22.5 mm |
|---|
| Sale per indivisible quantity | 1 |
|---|
| Shape of signaling unit head | Round |
|---|
| Type of operator | stay put |
|---|
| Operator profile | Red standard handle |
|---|
| Operator position information | 2 positions 90° |
|---|
| Contacts type and composition | 1 NO + 1 NC |
|---|
| Contact operation | Slow-break |
|---|
| Connections - terminals | Screw clamp terminals, = 1 x 0.22 mm² without cable end conforming to IEC 60947-1 |
|---|
| Light source | Universal LED |
|---|
| Bulb base | Integral LED |
|---|
| [Us] rated supply voltage | 230...240 V AC at 50/60 Hz |
|---|
| Height | 47 mm |
|---|
| Width | 30 mm |
|---|
| Depth | 68 mm |
|---|
| Terminals description ISO n°1 | (13-14)NO · (21-22)NC |
|---|
| Product weight | 0.111 kg |
|---|
| Resistance to high pressure washer | 7000000 Pa at 55 °C, distance : 0.1 m |
|---|
| Contacts usage | Standard contacts |
|---|
| Positive opening | With conforming to IEC 60947-5-1 appendix K |
|---|
| Operating torque | 0.14 N.m NO changing electrical state |
|---|
| Mechanical durability | 1000000 cycles |
|---|
| Tightening torque | 0.8…1.2 N.m conforming to IEC 60947-1 |
|---|
| Shape of screw head | Cross compatible with Philips no 1 screwdriver · Cross compatible with pozidriv No 1 screwdriver · Slotted compatible with flat Ø 4 mm screwdriver · Slotted compatible with flat Ø 5.5 mm screwdriver |
|---|
| Contacts material | Silver alloy (Ag/Ni) |
|---|
| Short-circuit protection | 10 A cartridge fuse type gG conforming to IEC 60947-5-1 |
|---|
| [Ith] conventional free air thermal current | 10 A conforming to IEC 60947-5-1 |
|---|
| [Ui] rated insulation voltage | 600 V (pollution degree 3) conforming to IEC 60947-1 |
|---|
| [Uimp] rated impulse withstand voltage | 6 kV conforming to IEC 60947-1 |
|---|
| [Ie] rated operational current | 3 A at 240 V, AC-15, A600 conforming to IEC 60947-5-1 · 6 A at 120 V, AC-15, A600 conforming to IEC 60947-5-1 · 0.1 A at 600 V, DC-13, Q600 conforming to IEC 60947-5-1 · 0.27 A at 250 V, DC-13, Q600 conforming to IEC 60947-5-1 · 0.55 A at 125 V, DC-13, Q600 conforming to IEC 60947-5-1 · 1.2 A at 600 V, AC-15, A600 conforming to IEC 60947-5-1 |
|---|
| Electrical durability | 1000000 cycles, AC-15, 2 A at 230 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN 60947-5-1 appendix C · 1000000 cycles, AC-15, 3 A at 120 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN 60947-5-1 appendix C · 1000000 cycles, AC-15, 4 A at 24 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN 60947-5-1 appendix C · 1000000 cycles, DC-13, 0.2 A at 110 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN 60947-5-1 appendix C · 1000000 cycles, DC-13, 0.5 A at 24 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN 60947-5-1 appendix C |
|---|
| Electrical reliability | Λ < 10exp(-6) at 5 V and 1 mA in clean environment conforming to IEC 60947-5-4 · Λ < 10exp(-8) at 17 V and 5 mA in clean environment conforming to IEC 60947-5-4 |
|---|
| Signalling type | Steady |
|---|
| Supply voltage limits | 195…264 V AC |
|---|
| Current consumption | 14 mA |
|---|
| Service life | 100000 h at rated voltage and 25 °C |
|---|
| Surge withstand | 1 kV conforming to IEC 61000-4-5 |
|---|
| Device presentation | Complete product |
|---|
| Protective treatment | TH |
|---|