Schneider Electric ComPacT INS switch disconnector, rated 22A. switch disconnector, Compact INS63, 63A, with red rotary handle and yellow front, 4 poles.
Brand
Schneider Electric
Range / Series
ComPact
Rated current
63 A
Poles
4P
Mounting
fixed
IP rating
IP40
Weight
0.6 kg
Complete product informationProduct description and supplied technical information
switch disconnector, Compact INS63, 63A, with red rotary handle and yellow front, 4 poles. Genuine Schneider Electric product supplied by United Force.
Technical specifications
Range
ComPact
Product name
ComPacT INS
Product or component type
Switch disconnector
Poles description
4P
Network type
AC · DC
Network frequency
50/60 Hz
[Ie] rated operational current
AC-22A: 63 A AC 50/60 Hz 220/240 V · AC-22A: 63 A AC 50/60 Hz 380/415 V · AC-22A: 63 A AC 50/60 Hz 440/480 V · AC-22A: 63 A AC 50/60 Hz 500 V · AC-23A: 40 A AC 50/60 Hz 500 V · AC-23A: 63 A AC 50/60 Hz 220/240 V · AC-23A: 63 A AC 50/60 Hz 380/415 V · AC-23A: 63 A AC 50/60 Hz 440/480 V · DC-22A: 63 A DC 125 V 2 poles in series · DC-23A: 63 A DC 125 V 2 poles in series · DC-22A: 63 A DC 250 V 4 poles in series · DC-23A: 63 A DC 250 V 4 poles in series
[Ui] rated insulation voltage
690 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage
8 kV
[Ith] conventional free air thermal current
63 A at 60 °C
[Icm] rated short-circuit making capacity
15 kA switch-disconnector alone 500 V AC at 50/60 Hz · 75 kA with upstream protection circuit breaker 500 V AC at 50/60 Hz
[Ue] rated operational voltage
500 V AC 50/60 Hz · 250 V DC
Suitability for isolation
Yes
Contact position indicator
Yes
Visible break
No
Pollution degree
3
Control type
Rotary handle
Handle colour
Red
Mounting mode
Fixed
Mounting support
Plate · DIN rail
Upside connection
Front
Downside connection
Front
Cable cross section
1.5…50 mm²
Maximum power
AC-23: 15 kW at 220/240 V AC 50/60 Hz · AC-23: 22 kW at 500/525 V AC 50/60 Hz · AC-23: 30 kW at 380/415 V AC 50/60 Hz · AC-23: 30 kW at 440 V AC 50/60 Hz
Rated duty
Uninterrupted
Intermittent duty class
Class 120 - 60 %
[Icw] rated short-time withstand current
0.67 kA during 20 s conforming to IEC 60947-3 · 1.73 kA during 3 s conforming to IEC 60947-3 · 3 kA during 1 s conforming to IEC 60947-3 · 0.55 kA during 30 s conforming to IEC 60947-3
Mechanical durability
20000 cycles
Electrical durability
AC-22A: 1500 cycles 220/240 V AC 50/60 Hz · AC-22A: 1500 cycles 380/415 V AC 50/60 Hz · AC-22A: 1500 cycles 440 V AC 50/60 Hz · AC-22A: 1500 cycles 500 V AC 50/60 Hz · AC-23A: 1500 cycles 220/240 V AC 50/60 Hz · AC-23A: 1500 cycles 380/415 V AC 50/60 Hz · AC-23A: 1500 cycles 440 V AC 50/60 Hz · AC-23A: 1500 cycles 500 V AC 50/60 Hz · DC-22A: 1500 cycles 250 V DC 4 poles in series · DC-23A: 1500 cycles 250 V DC 4 poles in series