Schneider Electric ComPacT control unit. Control unit MicroLogic 5.0E, ComPacT NS630b to NS3200 fixed and manually operated, selective protections.
Control unit MicroLogic 5.0E, ComPacT NS630b to NS3200 fixed and manually operated, selective protections. Genuine Schneider Electric product supplied by United Force.
Technical specifications
| Range | ComPacT |
|---|
| Range of product | ComPacT NS630b...1600 new generation · ComPacT NS1600b...3200 new generation |
|---|
| Product or component type | Control unit |
|---|
| Trip unit name | MicroLogic 5.0 E |
|---|
| Trip unit technology | Electronic |
|---|
| Range compatibility | ComPacT NS630b...1600 · ComPacT NS1600b...3200 |
|---|
| Device application | Distribution |
|---|
| Number of poles | 3P · 4P |
|---|
| Protected poles description | 4t · 3t · 3t + N/2 |
|---|
| Trip unit protection functions | Selective protection |
|---|
| Protection type | L : for short time short-circuit protection · S : for overload protection (long time) · I : for instantaneous short-circuit protection |
|---|
| Trip unit rating | 630 A at 50 °C · 800 A at 50 °C · 1000 A at 50 °C · 1250 A at 50 °C · 1600 A at 50 °C · 2000 A at 50 °C · 2500 A at 50 °C · 3200 A at 50 °C |
|---|
| Network type | AC |
|---|
| Network frequency | 50/60 Hz |
|---|
| Circuit breaker mounting mode | Fixed |
|---|
| Long-time pick-up adjustment type Ir (thermal protection) | Adjustable 9 settings |
|---|
| [Ir] long-time protection pick-up adjustment range | 0.4...1 x In |
|---|
| Long-time protection delay adjustment type tr | Adjustable 9 settings |
|---|
| [tr] long-time protection delay adjustment range | 0.7…16.6 s at 7.2 x Ir · 0.7…24 s at 6 x Ir · 12.5…600 s at 1.5 x Ir |
|---|
| Thermal memory | 20 mn |
|---|
| Short-time protection pick-up adjustment type Isd | Adjustable 9 settings |
|---|
| [Isd] Short-time protection pick-up adjustment range | 1.5...10 x Ir |
|---|
| Short-time protection delay adjustment type tsd | Adjustable |
|---|
| [tsd] Short-time protection delay adjustment range | 0…0.4 s I²t=off · 0.1…0.4 s I²t=on |
|---|
| Instantaneous protection pick-up adjustment type Ii | Adjustable 9 settings |
|---|
| [Ii] instantaneous protection pick-up adjustment range | 2...15 x In · Off |
|---|
| Earth-leakage protection | Without |
|---|
| Zone selective interlocking ZSI | With |
|---|
| Local signalling | 3 LEDs (red) for electrical fault · 1 LED (red) for internal error · 1 LED (yellow) for overload |
|---|
| Display type | Digital display |
|---|
| Type of measurement | Energy meter |
|---|
| Communication of data | Measurement readout · Protection and alarm settings |
|---|
| Standards | IEC 60947-4-2 |
|---|
| Ambient air temperature for operation | -25…70 °C |
|---|
| Ambient air temperature for storage | -25…85 °C |
|---|
| Warranty (in months) | 18 |
|---|