Schneider Electric level control relay. level control relay, Harmony Control Relays, 5A, 1CO, 24…240V AC DC.
level control relay, Harmony Control Relays, 5A, 1CO, 24…240V AC DC. Genuine Schneider Electric product supplied by United Force.
Technical specifications
| Range of product | Harmony Control Relays |
|---|
| Relay type | Level control relay |
|---|
| Product or component type | Level control relay |
|---|
| Relay name | RM35L |
|---|
| Relay monitored parameters | Detection by discrete sensors |
|---|
| time delay | Adjustable 0.1...5 s, +/- 10 % Tt- time delay upon fault |
|---|
| Switching capacity in VA | 1250 VA |
|---|
| Minimum switching current | 10 mA at 5 V DC |
|---|
| Maximum switching current | 5 A AC/DC |
|---|
| power consumption | 5 VA AC |
|---|
| Utilisation category | AC-12 conforming to IEC 60947-5-1 · AC-13 conforming to IEC 60947-5-1 · AC-14 conforming to IEC 60947-5-1 · AC-15 conforming to IEC 60947-5-1 · DC-12 conforming to IEC 60947-5-1 · DC-13 conforming to IEC 60947-5-1 |
|---|
| Contacts type and composition | 2 C/O |
|---|
| Reset time | 1000 ms · 4000 ms |
|---|
| Maximum switching voltage | 250 V AC/DC |
|---|
| [Un] rated nominal voltage | 24...240 V AC/DC 50/60 Hz, non self-powered |
|---|
| Supply voltage limits | 20.4…264 V AC/DC |
|---|
| operating voltage tolerance | - 15 % + 10 % Un |
|---|
| Output contacts | 1 C/O |
|---|
| nominal output current | 5 A |
|---|
| delay at power up | 0.5 s |
|---|
| Measurement accuracy | +/- 10 % of the full scale value · +/- 20 % for the HS range |
|---|
| Repeat accuracy | +/- 2 % for time delay |
|---|
| Measurement error | 0.5 %/°C with temperature variation |
|---|
| Sensitivity adjustment | 5…100 % |
|---|
| Maximum supply current for sensors | 40 mA |
|---|
| Cable capacitance | 10 nF for probe cable |
|---|
| Marking | CE : EMC 89/336/EEC · CE : 73/23/EEC |
|---|
| Overvoltage category | III conforming to IEC 60664-1 |
|---|
| Insulation resistance | > 500 MOhm at 500 V DC between supply and relay output conforming to IEC 60255-5 · > 500 MOhm at 500 V DC between measurement and relay output conforming to IEC 60664-1 · > 1 MOhm at 500 V DC between supply and measurement conforming to IEC 60255-5 · > 500 MOhm at 500 V DC between supply and relay output conforming to IEC 60664-1 · > 500 MOhm at 500 V DC between measurement and relay output conforming to IEC 60255-5 · > 1 MOhm at 500 V DC between supply and measurement conforming to IEC 60664-1 |
|---|
| [Ui] rated insulation voltage | 250 V conforming to IEC 60664-1 |
|---|
| Operating position | Any position without derating |
|---|
| Connections - terminals | Screw terminals, 1 x 0.5...1 x 4 mm² (20 AWG...11 AWG) solid without cable end · Screw terminals, 2 x 0.5...2 x 2.5 mm² (20 AWG...14 AWG) solid without cable end · Screw terminals, 2 x 0.2...2 x 1.5 mm² (24 AWG...16 AWG) flexible with cable end · Screw terminals, 1 x 0.2...1 x 2.5 mm² (24 AWG...12 AWG) flexible with cable end |
|---|
| Tightening torque | 0.6…1 N.m conforming to IEC 60947-1 |
|---|
| Housing material | Polycarbonate |
|---|
| Local signalling | LED (yellow) for relay ON · LED (green) for power ON · LED (yellow) for timer ON |
|---|
| Mounting support | 35 mm symmetrical DIN rail conforming to IEC 60715 |
|---|
| Electrical durability | 100000 cycles |
|---|
| Mechanical durability | 30000000 cycles |
|---|
| Operating rate | <= 360 operations/hour full load |
|---|
| Safety reliability data | B10d = 170000 · MTTFd = 182.6 years |
|---|
| Width | 35 mm |
|---|
| Control type | Without test button |
|---|
| Immunity to microbreaks | 100 ms DC · 90 ms AC |
|---|
| Electromagnetic compatibility | Emission standard for industrial environments conforming to IEC 61000-6-4 · Emission standard for residential, commercial and light-industrial environments conforming to IEC 61000-6-3 · Immunity for industrial environments conforming to NF EN/IEC 61000-6-2 |
|---|
| Standards | IEC 60255-6 |
|---|