Schneider Electric voltage control relay. voltage control relay, Harmony Control Relays, 5A, 2CO, 0.05..5V AC DC , 24.240V AC DC.
voltage control relay, Harmony Control Relays, 5A, 2CO, 0.05...5V AC DC , 24..240V AC DC. Genuine Schneider Electric product supplied by United Force.
Technical specifications
| Range of product | Harmony Control Relays |
|---|
| Relay type | Multifunction voltage control relay |
|---|
| Product or component type | Voltage control relay |
|---|
| Relay name | RM35UA |
|---|
| Relay monitored parameters | Overvoltage or undervoltage detection |
|---|
| time delay | Adjustable 0.3...30 s, 0 + 10 % Tt- time delay upon fault |
|---|
| Switching capacity in VA | 1250 VA |
|---|
| Measurement range | 0.05...5 V AC/DC |
|---|
| Contacts type and composition | 2 C/O |
|---|
| Reset time | 1500 ms time delay |
|---|
| Maximum switching voltage | 250 V AC/DC |
|---|
| Minimum switching current | 10 mA at 5 V DC |
|---|
| Maximum switching current | 5 A AC/DC |
|---|
| operating voltage tolerance | - 15 % + 10 % Un |
|---|
| Supply voltage limits | 20.4…264 V AC/DC |
|---|
| Power consumption in VA | 0…3.5 VA AC |
|---|
| Maximum power consumption in W | 0.6 W DC |
|---|
| Control circuit frequency | 40...70 Hz +/- 10 % |
|---|
| Immunity to microbreaks | 10 ms |
|---|
| Resistance across terminals | 30 mOhm at E2-M terminals · 5 mOhm at E1-M terminals · 50 mOhm at E3-M terminals |
|---|
| Output contacts | 2 C/O |
|---|
| nominal output current | 5 A |
|---|
| Hysteresis | 5…50 % of threshold setting |
|---|
| Measurement accuracy | +/- 10 % of the full scale value |
|---|
| Polarity | Non reversible polarity on DC supply |
|---|
| delay at power up | 600 ms |
|---|
| Maximum measuring cycle | 30 ms measurement cycle as true rms value |
|---|
| Repeat accuracy | +/- 0.5 % for input and measurement circuit · +/- 2 % for time delay |
|---|
| Measurement error | +/- 0.05 %/°C with temperature variation · < 1 % over the whole range with voltage variation |
|---|
| Sensitivity scale | 0.05...0.5 V E1-M terminals · 0.3...3 V E2-M terminals · 0.5...5 V E3-M terminals |
|---|
| Threshold setting | 10...100 % |
|---|
| Quality labels | CE |
|---|
| Insulation resistance | > 500 MOhm at 500 V DC between supply and relay output conforming to IEC 60255-5 · > 500 MOhm at 500 V DC between measurement and relay output conforming to IEC 60664-1 · > 1 MOhm at 500 V DC between supply and measurement conforming to IEC 60255-5 · > 500 MOhm at 500 V DC between supply and relay output conforming to IEC 60664-1 · > 500 MOhm at 500 V DC between measurement and relay output conforming to IEC 60255-5 · > 1 MOhm at 500 V DC between supply and measurement conforming to IEC 60664-1 |
|---|
| Operating position | Any position without derating |
|---|
| Local signalling | LED (green) for power ON · LED (yellow) for relay ON |
|---|
| Overvoltage category | III conforming to IEC 60664-1 |
|---|
| [Ui] rated insulation voltage | 250 V conforming to IEC 60664-1 · 600 V conforming to IEC 60664-1 |
|---|
| Connections - terminals | Screw terminals, 1 x 0.5...1 x 4 mm² (20 AWG...11 AWG) solid without cable end · Screw terminals, 2 x 0.5...2 x 2.5 mm² (20 AWG...14 AWG) solid without cable end · Screw terminals, 1 x 0.2...2 x 2.5 mm² (24 AWG...12 AWG) flexible with cable end · Screw terminals, 2 x 0.2...2 x 1.5 mm² (24 AWG...16 AWG) flexible with cable end |
|---|
| Tightening torque | 0.6…1 N.m conforming to IEC 60947-1 |
|---|
| Housing material | Polycarbonate |
|---|
| Mounting support | 35 mm symmetrical DIN rail conforming to IEC 60715 |
|---|
| Electrical durability | 100000 cycles |
|---|
| Mechanical durability | 30000000 cycles |
|---|
| Operating rate | <= 360 operations/hour full load |
|---|
| Utilisation category | AC-12 conforming to IEC 60947-5-1 · AC-13 conforming to IEC 60947-5-1 · AC-14 conforming to IEC 60947-5-1 · AC-15 conforming to IEC 60947-5-1 · DC-12 conforming to IEC 60947-5-1 · DC-14 conforming to IEC 60947-5-1 |
|---|