Technical specifications
| Range of product | Modicon X80 |
|---|
| Product or component type | Power supply module |
|---|
| backplane compatibility | All backplane |
|---|
| advanced diagnostics available via network | Redundancy information · Redundancy test · Temperature sensing · Remaining lifetime · Uptime duration |
|---|
| Primary voltage | 100...240 V |
|---|
| Supply circuit type | AC |
|---|
| Secondary power | 15 W 3.3 V DC at -25…60 °C I/O module logic power supply · 40 W 24 V DC at -25…60 °C I/O module power supply and processor if 3.3 V not loaded |
|---|
| Primary voltage limit | 85...264 V |
|---|
| Network frequency | 50/60 Hz |
|---|
| Network frequency limits | 47…63 Hz |
|---|
| Apparent power | 0.13 kVA |
|---|
| Input current | 0.55 A 230 V · 1.1 A 115 V |
|---|
| Inrush current | 30 A 115 V · 60 A 230 V |
|---|
| I²t on activation | 1 A².s 115 V · 4 A².s 230 V |
|---|
| It on activation | 0.1 A.s 115 V · 0.15 A.s 230 V |
|---|
| MTBF reliability | 792000 H |
|---|
| Protection type | Internal fuse not accessible for primary circuit · Overload protection for secondary circuit · Overvoltage protection for secondary circuit · Short-circuit protection for secondary circuit |
|---|
| Current at secondary voltage | 4.5 A 3.3 V DC I/O module logic power supply · 1.67 A 24 V DC I/O module power supply and processor |
|---|
| Maximum power dissipation in W | 8.5 W |
|---|
| Status LED | 1 LED (green) presence of voltages (OK) · 1 LED (green) redundancy OK · 1 LED (green) power supply status |
|---|
| Control type | RESET push-button cold restart |
|---|
| Electrical connection | 1 connector 2 pin(s)alarm relay · 1 connector 5 pin(s)line supply, protective earth |
|---|
| Insulation resistance | >= 100 MOhm primary/ground · >= 100 MOhm primary/secondary |
|---|
| Product weight | 0.51 kg |
|---|
| Immunity to microbreaks | 10 ms |
|---|
| Dielectric strength | 1500 V primary/secondary I/O module logic power supply · 1500 V primary/secondary I/O module power supply and processor · 2300 V primary/secondary sensor power supply · 1500 V primary/ground · 500 V 24 V sensor output/ground |
|---|
| Vibration resistance | 3 gn |
|---|
| Shock resistance | 15 gn |
|---|
| IP degree of protection | IP20 |
|---|
| Directives | 2014/30/EU - electromagnetic compatibility · 2006/42/EC - machinery · 2014/34/EU - ATEX directive |
|---|
| Product certifications | CE · UL · CSA · RCM · EAC · Merchant Navy · ATEX zone 2/22 · IECEx zone 2/22 · TÜV |
|---|
| Standards | IEC 61131-2 · IEC 61010-2-201 · UL 61010-2-201 · CSA C22.2 No 61010-2-201 · IACS E10 · EN/IEC 61000-6-5, interface type 1 and type 2 · EN/IEC 61850-3, location G · IEC 60079-0 |
|---|
| Environmental characteristic | Hazardous location class I division 2 · Gas resistant class Gx conforming to ISA S71.04 · Gas resistant class 3C4 conforming to IEC 60721-3-3 · Dust resistant class 3S4 conforming to IEC 60721-3-3 · Sand resistant class 3S4 conforming to IEC 60721-3-3 · Salt resistant level 2 conforming to IEC 68252 · Mold growth resistant class 3B2 conforming to IEC 60721-3-3 · Fungal spore resistant class 3B2 conforming to IEC 60721-3-3 |
|---|
| Ambient air temperature for storage | -40…85 °C |
|---|
| Ambient air temperature for operation | -25…60 °C |
|---|
| Relative humidity | 5…95 % at 55 °C without condensation |
|---|
| Protective treatment | Conformal coating |
|---|
| Operating altitude | 0...2000 m · 2000...5000 m with derating factor |
|---|
| Unit Type of Package 2 | S03 |
|---|
| Number of Units in Package 2 | 6 |
|---|
| Package 2 Height | 30.000 cm |
|---|
| Package 2 Width | 30.000 cm |
|---|
| Package 2 Length | 40.000 cm |
|---|
| Package 2 Weight | 4.479 kg |
|---|
| Warranty (in months) | 18 |
|---|