Schneider Electric Linergy TR terminal block, rated 125 A. Terminal block, Linergy TR, grey, 35mm², passthrough, 2 points, set of 10.
Terminal block, Linergy TR, grey, 35mm², passthrough, 2 points, set of 10. Genuine Schneider Electric product supplied by United Force.
Technical specifications
| Range | Linergy |
|---|
| Product name | Linergy TR |
|---|
| Product or component type | Terminal block |
|---|
| Device short name | TRV |
|---|
| Terminal block type | Passthrough |
|---|
| Terminal block level | 1 |
|---|
| Mounting mode | Clip-on |
|---|
| Nominal cross section | 35 mm² |
|---|
| Length | 60.2 mm |
|---|
| Colour | Grey |
|---|
| Quantity per set | Set of 50 |
|---|
| Width | 16 mm |
|---|
| Height | 65.7 mm |
|---|
| Connections - terminals | 1 x screw terminal: upstream · 1 x screw terminal: downstream |
|---|
| number of connections | 2 |
|---|
| Connection position | Sideways |
|---|
| Number of measurement input | 2 |
|---|
| Cable cross section | 1.5…50 mm², flexible cable without cable end · 1.5…50 mm², solid cable |
|---|
| Tightening torque | 3.2…3.7 N.m |
|---|
| Wire stripping length | 18 mm |
|---|
| Tool type | Connection: screwdriver · Disconnection: screwdriver |
|---|
| [Ue] rated operational voltage | 1000 V conforming to EN/IEC 60947-7-1 · 600 V CSA · 600 V UL |
|---|
| [In] rated current | 125 A conforming to EN/IEC 60947-7-1 · 150 A UL · 150 A CSA |
|---|
| Material | Polyamide 6/6: insulating case |
|---|
| Dielectric loss | 0.01 at 1 MHz conforming to IEC 60250 · 0.01 at 1 MHz conforming to VDE 0303-T4 |
|---|
| Dielectric constant | 3.7 at 1 MHz |
|---|
| Resistivity | 10000 MΩ.m conforming to IEC 60093 · 10000 MΩ.m conforming to VDE 0303-T30 |
|---|
| Surface resistance | 1000 GΩ conforming to IEC 60093 · 1000 GΩ conforming to VDE 0303-T30 |
|---|
| Creep resistance | 500 CTI (> 400 kB) conforming to IEC 60093 · 500 CTI (> 400 kB) conforming to VDE 0303-T30 |
|---|
| Flame retardance | V0, thickness0.8 mm conforming to UL 94 |
|---|
| Product weight | 61 g |
|---|
| Range compatibility | PrismaSeT G · PrismaSeT P · PrismaSet HD · PrismaSeT Pack 250 · PanelSeT · Mureva · PrismaSeT XS · TeSys |
|---|
| Product compatibility | Spacial enclosures |
|---|
| Product certifications | VDE · GL · CSA · UL |
|---|
| Dielectric strength | 1000 V conforming to IEC 60243-1 |
|---|
| Ambient air temperature for operation | -40…130 °C conforming to IEC 60216-1 · -40…130 °C conforming to VDE 0304-T21 |
|---|
| Unit Type of Package 2 | BB1 |
|---|
| Number of Units in Package 2 | 50 |
|---|
| Package 2 Height | 9.500 cm |
|---|
| Package 2 Width | 17.700 cm |
|---|
| Package 2 Length | 28.000 cm |
|---|
| Package 2 Weight | 2.964 kg |
|---|
| Unit Type of Package 3 | S06 |
|---|
| Number of Units in Package 3 | 2000 |
|---|
| Package 3 Height | 75.000 cm |
|---|