Schneider Electric soft starter. soft starter for asynchronous motor, Altistart 01, ATS01, 22A, 200 to 240V, 4 to 5.5kW.
soft starter for asynchronous motor, Altistart 01, ATS01, 22A, 200 to 240V, 4 to 5.5kW. Genuine Schneider Electric product supplied by United Force.
Technical specifications
| Range of product | Altistart 01 |
|---|
| Product destination | Asynchronous motors |
|---|
| Product or component type | Soft starter |
|---|
| Product specific application | Simple machine |
|---|
| Device short name | ATS01 |
|---|
| Network number of phases | 3 phases |
|---|
| [Us] rated supply voltage | 200...240 V - 10...10 % |
|---|
| Motor power kW | 4 kW, 3 phases at 200...240 V · 5.5 kW, 3 phases at 200...240 V |
|---|
| Motor power hp | 5 hp, 3 phases at 200...240 V · 7.5 hp, 3 phases at 200...240 V |
|---|
| IcL starter rating | 22 A |
|---|
| Utilisation category | AC-53B conforming to EN/IEC 60947-4-2 |
|---|
| Current consumption | 110 A at nominal load |
|---|
| Type of start | Start with voltage ramp |
|---|
| Power dissipation in W | 124.5 W in transient state · 4.5 W at full load and at end of starting |
|---|
| Assembly style | With heat sink |
|---|
| Function available | Integrated bypass |
|---|
| Supply voltage limits | 180…264 V |
|---|
| Supply frequency | 50...60 Hz - 5...5 % |
|---|
| Network frequency | 47.5...63 Hz |
|---|
| Output voltage | <= power supply voltage |
|---|
| [Uc] Control circuit voltage | Built into the starter |
|---|
| Starting time | 1 s / 100 · 5 s / 20 · 10 s / 10 · Adjustable from 1 to 10 s |
|---|
| Deceleration time symb | Adjustable from 1 to 10 s |
|---|
| Starting torque | 30...80 % of starting torque of motor connected directly on the line supply |
|---|
| Discrete input type | Logic (LI1, LI2, BOOST) stop, run and boost on start-up functions <= 8 mA 27 kOhm |
|---|
| Discrete input voltage | 24...40 V |
|---|
| Discrete input logic | Positive LI1, LI2, BOOST at State 0: 13 V, >= 0.5 mA |
|---|
| Discrete output current | 2 A DC-13 · 3 A AC-15 |
|---|
| Discrete output type | Open collector logic LO1 end of starting signal · Relay outputs R1A, R1C NO |
|---|
| Discrete output voltage | 24 V (voltage limits: 6...30 V) open collector logic |
|---|
| Minimum switching current | 10 mA at 6 V DC for relay outputs |
|---|
| Maximum switching current | Relay outputs: 2 A at 250 V AC cos phi = 0.5 and L/R = 20 ms inductive load · Relay outputs: 2 A at 30 V DC cos phi = 0.5 and L/R = 20 ms inductive load |
|---|
| Display type | 1 LED (green) for starter powered up · 1 LED (yellow) for nominal voltage reached |
|---|
| Tightening torque | 0.5 N.m · 1.9…2.5 N.m |
|---|
| Electrical connection | 4 mm screw clamp terminal - rigid 1 1...10 mm² 8 AWG power circuit · Screw connector - rigid without cable end 1 0.5...2.5 mm² 14 AWG control circuit · 4 mm screw clamp terminal - rigid 2 1...6 mm² 10 AWG power circuit · Screw connector - rigid 2 0.5...1 mm² 17 AWG control circuit · Screw connector - flexible with cable end 1 0.5...1.5 mm² 16 AWG control circuit · 4 mm screw clamp terminal - flexible without cable end 1 1.5...10 mm² 8 AWG power circuit · Screw connector - flexible without cable end 1 0.5...2.5 mm² 14 AWG control circuit · 4 mm screw clamp terminal - flexible with cable end 2 1...6 mm² 10 AWG power circuit · 4 mm screw clamp terminal - flexible without cable end 2 1.5...6 mm² 10 AWG power circuit · Screw connector - flexible without cable end 2 0.5...1.5 mm² 16 AWG control circuit |
|---|
| Marking | CE |
|---|
| Operating position | Vertical +/- 10 degree |
|---|
| Height | 154 mm |
|---|
| Width | 45 mm |
|---|
| Depth | 131 mm |
|---|
| Product weight | 0.56 kg |
|---|
| Compatibility code | ATS01N2 |
|---|
| Power range | 4…6 kW at 200…240 V 3 phases |
|---|
| Motor starter type | Soft starter |
|---|
| Electromagnetic compatibility | Conducted and radiated emissions level B conforming to CISPR 11 · Conducted and radiated emissions level B conforming to IEC 60947-4-2 · Damped oscillating waves level 3 conforming to IEC 61000-4-12 · Electrostatic discharge level 3 conforming to IEC 61000-4-2 · EMC immunity level 3 conforming to EN 50082-1 · EMC immunity level B conforming to EN 50082-2 · Harmonics level 3 conforming to IEC 1000-3-2 · Harmonics level 3 conforming to IEC 1000-3-4 · Immunity to conducted interference caused by radio-electrical fields level 3 conforming to IEC 61000-4-6 · Immunity to electrical transients level 4 conforming to IEC 61000-4-4 · Immunity to radiated radio-electrical interference level 3 conforming to IEC 61000-4-3 · Micro-cuts and voltage fluctuation conforming to IEC 61000-4-11 · Voltage/current impulse level 3 conforming to IEC 61000-4-5 |
|---|