Schneider Electric soft starter. soft starter for asynchronous motor, Altistart 01, ATS01, 6A, 380 to 415V, 1.5 to 3kW.
Brand
Schneider Electric
Rated current
6 A
Voltage
415 V
IP rating
IP20
Weight
0.42 kg
Complete product informationProduct description and supplied technical information
soft starter for asynchronous motor, Altistart 01, ATS01, 6A, 380 to 415V, 1.5 to 3kW. Genuine Schneider Electric product supplied by United Force.
Technical specifications
Range of product
Altistart 01
Product destination
Asynchronous motors
Product or component type
Soft starter
Product specific application
Simple machine
Device short name
ATS01
Network number of phases
3 phases
[Us] rated supply voltage
380...415 V - 10...10 %
Motor power kW
3 kW, 3 phases at 380...415 V · 1.5 kW, 3 phases at 380...415 V · 2.2 kW, 3 phases at 380...415 V
IcL starter rating
6 A
Utilisation category
AC-53B conforming to EN/IEC 60947-4-2
Current consumption
30 A at nominal load
Type of start
Start with voltage ramp
Power dissipation in W
4 W at full load and at end of starting · 64 W in transient state
Assembly style
With heat sink
Function available
Integrated bypass
Supply voltage limits
342…456 V
Supply frequency
50...60 Hz - 5...5 %
Network frequency
47.5...63 Hz
Output voltage
<= power supply voltage
[Uc] Control circuit voltage
Built into the starter
Starting time
1 s / 100 · 5 s / 20 · 10 s / 10 · Adjustable from 1 to 10 s
Deceleration time symb
Adjustable from 1 to 10 s
Starting torque
30...80 % of starting torque of motor connected directly on the line supply
Discrete input type
Logic (LI1, LI2, BOOST) stop, run and boost on start-up functions <= 8 mA 27 kOhm
Discrete input voltage
24...40 V
Discrete input logic
Positive LI1, LI2, BOOST at State 0: 13 V, >= 0.5 mA
Discrete output current
2 A DC-13 · 3 A AC-15
Discrete output type
Open collector logic LO1 end of starting signal · Relay outputs R1A, R1C NO
Discrete output voltage
24 V (voltage limits: 6...30 V) open collector logic
Minimum switching current
10 mA at 6 V DC for relay outputs
Maximum switching current
Relay outputs: 2 A at 250 V AC cos phi = 0.5 and L/R = 20 ms inductive load · Relay outputs: 2 A at 30 V DC cos phi = 0.5 and L/R = 20 ms inductive load
Display type
1 LED (green) for starter powered up · 1 LED (yellow) for nominal voltage reached
Tightening torque
1.9…2.5 N.m · 0.5 N.m
Electrical connection
4 mm screw clamp terminal - rigid 1 1...10 mm² 8 AWG power circuit · Screw connector - rigid without cable end 1 0.5...2.5 mm² 14 AWG control circuit · 4 mm screw clamp terminal - rigid 2 1...6 mm² 10 AWG power circuit · Screw connector - rigid 2 0.5...1 mm² 17 AWG control circuit · Screw connector - flexible with cable end 1 0.5...1.5 mm² 16 AWG control circuit · 4 mm screw clamp terminal - flexible without cable end 1 1.5...10 mm² 8 AWG power circuit · Screw connector - flexible without cable end 1 0.5...2.5 mm² 14 AWG control circuit · 4 mm screw clamp terminal - flexible with cable end 2 1...6 mm² 10 AWG power circuit · 4 mm screw clamp terminal - flexible without cable end 2 1.5...6 mm² 10 AWG power circuit · Screw connector - flexible without cable end 2 0.5...1.5 mm² 16 AWG control circuit
Marking
CE
Operating position
Vertical +/- 10 degree
Height
124 mm
Width
45 mm
Depth
131 mm
Product weight
0.42 kg
Compatibility code
ATS01N2
Power range
1.1…2 kW at 380…440 V 3 phases · 2.2…3 kW at 380…440 V 3 phases
Motor starter type
Soft starter
Electromagnetic compatibility
Conducted and radiated emissions level B conforming to CISPR 11 · Conducted and radiated emissions level B conforming to IEC 60947-4-2 · Damped oscillating waves level 3 conforming to IEC 61000-4-12 · Electrostatic discharge level 3 conforming to IEC 61000-4-2 · EMC immunity level 3 conforming to EN 50082-1 · EMC immunity level B conforming to EN 50082-2 · Harmonics level 3 conforming to IEC 1000-3-2 · Harmonics level 3 conforming to IEC 1000-3-4 · Immunity to conducted interference caused by radio-electrical fields level 3 conforming to IEC 61000-4-6 · Immunity to electrical transients level 4 conforming to IEC 61000-4-4 · Immunity to radiated radio-electrical interference level 3 conforming to IEC 61000-4-3 · Micro-cuts and voltage fluctuation conforming to IEC 61000-4-11 · Voltage/current impulse level 3 conforming to IEC 61000-4-5