Schneider Electric soft starter, rated 17 A. Soft starter, Altivar Soft Starter ATS430, 17A, 208 to 600V AC, control supply 110 to 230V AC.
Soft starter, Altivar Soft Starter ATS430, 17A, 208 to 600V AC, control supply 110 to 230V AC. Genuine Schneider Electric product supplied by United Force.
Technical specifications
| Range of product | Altivar Soft Starter ATS430 |
|---|
| Product or component type | Soft starter |
|---|
| Product destination | Asynchronous motors |
|---|
| Product specific application | Standard industrial machines |
|---|
| Device short name | ATS430 |
|---|
| Network number of phases | 3 phases |
|---|
| Utilisation category | AC-3A · AC-53A |
|---|
| Ue power supply voltage | 208...600 V AC (- 15...10 %) |
|---|
| power supply frequency | 50...60 Hz - 20...20 % |
|---|
| [Ie] rated operational current | Normal duty: 17 A in line (at <40 °C) |
|---|
| Service factor at Ie | 100 |
|---|
| Torque control | True |
|---|
| IP degree of protection | IP20 |
|---|
| Motor power kW | 4 kW at 230 V in line normal duty · 7.5 kW at 400 V in line normal duty · 7.5 kW at 440 V in line normal duty · 9 kW at 500 V in line normal duty · 9 kW at 525 V in line normal duty |
|---|
| Motor power hp | 3 hp at 208 V normal duty · 5 hp at 230 V normal duty · 10 hp at 460 V normal duty · 15 hp at 575 V normal duty |
|---|
| Communication port protocol | Modbus serial |
|---|
| Device connection | In line |
|---|
| Overload current | 400 % Ie for 13 s |
|---|
| On-load factor | 50 % |
|---|
| Operating cycles/hour | 10 cyc/h |
|---|
| [Us] control circuit voltage | 110...230 V AC 50...60 Hz - 15...10 % |
|---|
| Apparent power | 70 VA |
|---|
| Integrated motor overload protection | True |
|---|
| motor thermal protection class | Class 10E |
|---|
| Protection type | Phase failure: mains · Thermal protection: mains · Thermal protection: starter · Current overload: motor · Motor underload: motor · Excessive acceleration time: motor · Motor phase loss detection: motor · Protection against line phase inversion: mains · External thermal protection: motor · Short-circuit between motor phase and earth: motor |
|---|
| current limiting %In (5 x Ie maximum) | 150…700 % |
|---|
| Rated current pwr loss specification | 17 A |
|---|
| Power loss static current independent | 19 W |
|---|
| Power loss per device current dependent | 2 W |
|---|
| Power loss during starting | 133 W during starting at 40 °C at 400% In |
|---|
| Standards | EN/IEC 60947-4-2 · UL 60947-4-2 · IEC 60664-1 |
|---|
| Product certifications | cULus · CE · UKCA · CCC · RCM · EAC · KC |
|---|
| Marking | CULus · CE · UKCA · CCC · RCM · EAC · KC |
|---|
| [Uc] control circuit voltage | 24 V DC |
|---|
| Discrete input number | 4 |
|---|
| Discrete input type | (STOP) digital input, 4.4 kOhm · (RUN) digital input, 4.4 kOhm · (DI3) digital input, 4.4 kOhm · (DI4) digital input, 4.4 kOhm |
|---|
| Input compatibility | STOP: digital input level 1 PLC conforming to EN/IEC 61131-2 · RUN: digital input level 1 PLC conforming to EN/IEC 61131-2 · DI3: digital input level 1 PLC conforming to EN/IEC 61131-2 · DI4: digital input level 1 PLC conforming to EN/IEC 61131-2 |
|---|
| Discrete input logic | Digital input STOP at State 0: 0... 11 V, >= 5 mA · Digital input RUN at State 0: 0... 11 V, >= 5 mA · Digital input DI3 at State 0: 0... 11 V, >= 5 mA · Digital input DI4 at State 0: 0... 11 V, >= 5 mA |
|---|
| Relay output number | 2 |
|---|
| Relay output type | Relay outputs R1A, R1C NO · Relay outputs R1B, R1C NC · Relay outputs R2A, R2C NO |
|---|
| Minimum switching current | 100 mA at 12 V DC for relay outputs |
|---|
| Maximum switching current | Relay outputs 2 A / 250 V AC for AC-15 100000 cycles following IEC 60947-5-1 · Relay outputs 2 A / 30 V DC for DC-13 150000 cycles following IEC 60947-5-1 |
|---|
| Analogue input number | 1 |
|---|
| Analogue input type | PTC1 : PTC temperature probe · PTC2 : PTC temperature probe |
|---|
| Analogue output number | 1 |
|---|