Technical specifications
| Range | ComPacT |
|---|
| Range of product | ComPacT NSX400...630 |
|---|
| Product or component type | Trip unit |
|---|
| Trip unit name | MicroLogic 6.3 E |
|---|
| Trip unit technology | Electronic |
|---|
| Range compatibility | ComPacT NSX630 |
|---|
| Device application | Distribution |
|---|
| Poles description | 3P |
|---|
| Protected poles description | 3D |
|---|
| Trip unit protection functions | LSIG |
|---|
| Protection type | L : for overload protection (long time) · S : for short time short-circuit protection · I : for instantaneous short-circuit protection · G : for ground fault protection |
|---|
| Trip unit rating | 630 A at 40 °C |
|---|
| [Ue] rated operational voltage | 690 V AC 50/60 Hz |
|---|
| Network type | AC |
|---|
| Network frequency | 50/60 Hz |
|---|
| Circuit breaker mounting mode | Fixed |
|---|
| Long-time pick-up adjustment type Ir (thermal protection) | Adjustable |
|---|
| [Ir] long-time protection pick-up adjustment range | 250...630 A |
|---|
| Long-time protection delay adjustment type tr | Adjustable |
|---|
| [tr] long-time protection delay adjustment range | 15…400 s at 1.5 x Ir · 0.35…11 s at 7.2 x Ir · 0.5…16 s at 6 x Ir |
|---|
| Thermal memory | 20 minutes before and after tripping |
|---|
| Short-time protection pick-up adjustment type Isd | Adjustable |
|---|
| [Isd] Short-time protection pick-up adjustment range | 1.5...10 x Ir |
|---|
| Short-time protection delay adjustment type tsd | Adjustable |
|---|
| [tsd] Short-time protection delay adjustment range | 0…0.4 s I²t=off · 0.1…0.4 s I²t=on |
|---|
| Instantaneous protection pick-up adjustment type Ii | Adjustable |
|---|
| [Ii] instantaneous protection pick-up adjustment range | 1.5...11 x In |
|---|
| Ground-fault protection pick-up adjustment type Ig | Adjustable |
|---|
| [Ig] ground-fault protection pick-up adjustment range | 0.4...1 x In for In = 40 A · 0.2...1 x In for In > 40 A · Ig enable on/off |
|---|
| Ground-fault protection time delay adjustment type tg | Adjustable |
|---|
| [tg] ground-fault protection time delay adjustment range | 0…0.4 s I²t=off · 0.1…0.4 s I²t=on |
|---|
| Earth-leakage protection | Without |
|---|
| Zone selective interlocking ZSI | With |
|---|
| Local signalling | Flashing LED (green) for ready to operate · LED 105 % Ir (red) for overload · LED 90 % Ir (orange) for overload |
|---|
| Display type | LCD display |
|---|
| Type of measurement | Energy meter |
|---|
| Communication of data | Energy metering · Protection and alarm settings · Time-stamped histories and event tables · Instantaneous and demand values · Maintenance indicators · Demand current and power · Power quality · Maximeters/minimeters |
|---|
| Electrical data recording | Maintenance indicators |
|---|
| Standards | EN/IEC 60947-2 |
|---|
| Electrical shock protection class | Class II |
|---|
| Pollution degree | 3 conforming to IEC 60947-1 |
|---|
| IP degree of protection | IP40 conforming to IEC 60529 |
|---|
| Ambient air temperature for operation | -25…70 °C |
|---|
| Ambient air temperature for storage | -40…85 °C |
|---|
| Unit Type of Package 2 | S03 |
|---|