Schneider Electric PowerLogic capacitor bank. automatic PowerLogic PFC Capacitor bank, 450kvar DR3,8 with incomer CB xxB 400V 60Hz.
automatic PowerLogic PFC Capacitor bank, 450kvar DR3,8 with incomer CB xxB 400V 60Hz. Genuine Schneider Electric product supplied by United Force.
Technical specifications
| Network rated voltage | 400 V AC 60 Hz · 415 V AC 60 Hz |
|---|
| Reactive power rating | 450 kvar |
|---|
| Operating mode | Automatic |
|---|
| Range | PowerLogic |
|---|
| Device short name | automatic capacitor bank with detuned reactor |
|---|
| Product or component type | Capacitor bank |
|---|
| Network pollution level | Polluted |
|---|
| [Gh/Sn] harmonic pollution rate | 25…50 % |
|---|
| [THDU] total harmonic distorsion of voltage | 4…7 % |
|---|
| Tuning factor | 3.8 |
|---|
| Tuning frequency | 228 Hz |
|---|
| Power per step | 50 kvar |
|---|
| Step composition | 50 + 4x100 |
|---|
| Location of connection | Bottom |
|---|
| Controller type | PowerLogic PFC Controller VPL6 |
|---|
| capacitor technology | PowerLogic PFC Capacitor + Detuned Reactor |
|---|
| Poles description | 3P |
|---|
| Capacitance tolerance | - 5 % to 10 % |
|---|
| [Ui] rated insulation voltage | 800 V |
|---|
| [Uimp] rated impulse withstand voltage | 8 kV |
|---|
| Maximum permissible voltage | 1.1 x Un (8 hours over 24 hours) conforming to IEC 60831 |
|---|
| [Imp] maximum permanent current | Capacitor: 1.8 x In at 480 V conforming to IEC 60831 · Battery: 1.19 x In at 400 V conforming to IEC 61439-2 · Battery: 1.19 x In at 415 V conforming to IEC 61439-2 |
|---|
| main incomer protection | Circuit breaker protection |
|---|
| Breaking capacity | Icu 50 kA |
|---|
| Control type | Rotary handle |
|---|
| Step protection type | Overload: harmonic control from PowerLogic PFC Controller · Short-circuit: fuse |
|---|
| Accessibility for operation | Front |
|---|
| Colour | Grey (RAL 7035) |
|---|
| maximum weight | 952 kg |
|---|
| Height | 2200 mm |
|---|
| Width | Capacitor: 800 mm · Detuned reactor: 600 mm |
|---|
| Depth | 600 mm |
|---|
| Provided equipment | Auxiliary transformer |
|---|
| Internal voltage transformer | 400/230 V - 1000 VA |
|---|
| Function available | Alarm contact · GenSet shedding contact |
|---|
| Standards | IEC 61439-2 · IEC 61439-1 · IEC 61921 |
|---|
| Product certifications | CE · ASEFA · EAC |
|---|
| Mounting location | Indoor |
|---|
| IP degree of protection | Environment: IP31 · Safety: IPxx B |
|---|
| IK degree of protection | IK10 |
|---|
| Relative humidity | 0…95 % |
|---|
| Operating altitude | <= 2000 m |
|---|
| Ambient air temperature for operation | -5…45 °C |
|---|
| Average ambient air temperature for operation | 35 °C (annual) · 45 °C (over 24 hours) |
|---|
| Warranty (in months) | 18 |
|---|